(1) When using the device, pay attention to the maintenance of the control box, sensor and transmission parts to avoid damage.
(2) Connect the pipes in the direction indicated by the arrow on the body of the self-cleaning filter so that the water flow direction is the same as the arrow on the body.
(3) The self-cleaning filter should be installed before the water equipment requiring maintenance and as close as possible to the water equipment.
(4) In the power system, the self-cleaning filter should be installed between the pump and the water equipment, and the closer it is to the water equipment, the better. When the pressure between the pump and the water equipment exceeds the limit pressure of the filter, the self-cleaning filter can also be installed in front of the water pump and as close as possible to the water pump.
(5) The connection method of the active drain valve is divided into flange and thread. The drain pipe should not be too long, and try not to exceed 10 meters.
(6) When installing, it should be considered to be convenient for inspection and repair. Valves should be shut off before and after the self-cleaning filter, and bypass pipelines should be installed. There should be enough space for maintenance on both sides of the self-cleaning filter, and a space close to the length of the cylinder should be reserved in the direction of the filter cartridge to replace the filter screen.
(7) The standard of the self-cleaning filter should match the pipeline or flow. When a single filter cannot meet the system flow requirements, two or more can be connected in parallel to achieve the system filtration requirements. When adopting any type of device, care should be taken to make the outlet direction of the active blowdown valve horizontal or downward to ensure more effective blowdown.
(8) When the self-cleaning filter device is outdoors, please pay attention to waterproof and rainproof.